Conference Room Rapid SCIF - X240-40-KL


The Conference Room SCIF is built to ICD 705 standards for SCIF or SAPF accreditation. It serves as a conference or briefing room to hold up to 8 people (no workstations). It meets STC 50 acoustic protection and the minimum TEMPEST recommendations, as dictated by the ICD 705 Tech Spec V1.5.
Government Accredited Meeting Facility
Portable SCIF Building
Turn-Key Conference Container
Seating for up to 8 personnel
Specifications:
Number of Workstations: 1-4, 24” fixed plastic laminate countertop
RF Shielding: Standard or Enhanced**
IDS/ ACS: Power and Pathway (No system included)
CCTV: 19” monitor and camera
Cooling: 5-ton
Doors: 3'0" x 6'8" STC 50 rated entry door, 3'0" x 6'8" solid core wood secondary door
Electrical: 120/208V 100 Amp, 3-phase panel, 10 receptacles, 4 30A twist-lock receptacles
Flooring: 2' x 2' carpet tile in workspace, 12” x 12” VCT in server room
Data: One 1” surface-mounted unsecure data conduit (low), one 1” surface-mounted secure data conduit (high), space for four data racks (racks not provided)
Delivery (continental U.S.): Yes
-
Number of Workstations: 1-4, 24” fixed plastic laminate countertop
-
RF Shielding: Standard or Enhanced**
-
IDS/ ACS: Power and Pathway (No system included)
-
CCTV: 19” monitor and camera
-
Cooling: 5-ton
-
Doors: 3'0" x 6'8" STC 50 rated entry door, 3'0" x 6'8" solid core wood secondary door
-
Electrical: 120/208V, 100 Amp, 3-phase panel, 11 receptacles
-
Flooring: 2' x 2' carpet tile
-
Data: One 1” surface-mounted unsecure data conduit (low), one 1” surface-mounted secure data conduit (high), two 12U
-
Power/Data Cabling: Included for A/V display in conference room
-
Delivery (continental U.S.): Yes
**Enhanced RF shielding requires additional fee and longer fabrication time
Exterior: 8’ (w) x 40’ (l) x 8’6” (h)
Interior: 6’10” (w) x 33’11” (l) x 7’3” (h)
Approximate weight: 15,000 lbs
Details
This 40-foot ISO shipping container is built to ICD 705 standards for SCIF or SAPF accreditation. It’s divided in half with an interior wall and door to serve as both a conference or briefing room to hold up to 8 people and as a workspace to accommodate 1-3 workstations. The workspace includes a work surface plus two (2) shielded Cat 6 network connections per workstation. The container meets STC 50 acoustic protection and the minimum TEMPEST recommendations, as dictated by the ICD 705 Tech Spec V1.5.1. The RapidX240 includes a Kaba Mas X10 series locking device, prep for security systems, CCTV, and five (5) tons of cooling with a split ductless HVAC system. Includes power/data cabling for A/V display (one location), 11 electrical receptacles, wall-mounted server rack and patch panel for network. Walls are smooth-face FRP, which acts as dry-erase display walls, and furnishings can be included for additional fee. Each Rapid SCIF container includes unlimited accreditation consulting support, including draft sections of Construction Security Plan (CSP), and Pre- Construction Checklist, construction information for your Fixed Facility Checklist (FFC), and photo documentation.
Model Number: Rapid-SCIF-X240-40-KL