Wall C is suggested to be used for Plywood. The list below and accompanying diagram list all construction specifications for Wall C.
- Three layers of Gypsum Wall Board (GWB) ⅝ inch-thick
- Two layers on the uncontrolled side
- Sound group 4
- One layer over min. ½” plywood on the controlled side
- CTTA recommended countermeasures: (foil backed GWB or a layer of approved Ultra Radiant R-Foil) must be put up for RF shielding. In accordance with IAW, the foil will be located between the layer of plywood and GWB
- Two layers on the uncontrolled side
- ½” Plywood attached 8’ vertical by 4’ horizontal to 16 gauge studs using glue and #10 steel tapping screws at 12 o.c.
- Gypsum Wall Board must be mounted to the Plywood with screws and avoiding contact with studs to ease any acoustic flanking path
- 16 gauge continuous track (top and bottom) with anchors at 32” on center max.)
- Bed will be in a continuous bead of acoustical sealant
- Fire safe non-shrink grout, or acoustic sealant in all voids above/below track on both sides of the wall
- Entire wall shall be finished and painted from true floor to ceiling

Does your facility require a SCIF? KL Security offers SCIF Container Solutions with panelized modular systems for scalable modular, portable, & mobile requirements. We assist in the acquisition of modular facilities for DoD & Government Access Control and ICD705 SCIFs or SAPF facilities. We also assist with special access control planning and commercial business security.
Call 866-867-0306 or email [email protected] to see how the experts at KL Security can assist your facility in security needs.
Technical Specifications for Construction and Management of Sensitive Compartmented Information Facilities
SCIF Container Series | Part 1: Site Evaluation
SCIF Container Series | Part 2: Design Planning Checklist
SCIF Container Series | Part 3: Perimeter Wall Construction – Wall A
SCIF Container Series | Part 4: Perimeter Wall Specifications – Wall B
Information has been gathered from sources deemed reliable but not guaranteed and is subject to change without notice. The information contained in this site is provided for informational purposes only.